The system treats high sugar wastewater from fruit processing.
48 BioGill bioreactors are arranged in 3 treatment bays.

Location: NSW, Australia

Size: 150,000 litres per day

System Size: 48 x BioGill bioreactors, arranged in three treatment bays. Total 12,000m² of membrane.

Juice processing

Situation

To meet local government discharge regulations, this fruit processing centre was required to improve its onsite treatment of wastewater and reduce BOD prior to discharge to the sewer.

Solution

48 BioGill bioreactors were installed in three treatment bay areas. 

Design

Wastewater passes from the factory processing area through solids filtration into buffer tanks, then transferred to one of three treatment tanks. The wastewater is then pumped to the top of the gills and dispersed by gravity across the 48 bioreactors. Wastewater is circulated over the BioGills for 24 hours. Following the BioGill treatment process, the wastewater is pH adjusted prior to discharge.

Results

BOD reduction of 2500 mg/L is being achieved over a treatment cycle.